Abstract

Thick-section austenitic stainless steels have widespread industrial applications, especially in nuclear power plants. The joining methods used in the nuclear industry are primarily based on arc welding processes. However, it has recently been shown that narrow gap laser welding (NGLW) can weld materials with thicknesses that are well beyond the capabilities of single pass autogenous laser welding. The heat input for NGLW is much lower than for arc welding, as are the expected levels of residual stress and distortion. This paper reports on a preliminary investigation of the through-thickness 2D residual stresses distributions, distortions, and plastic strain characteristics, for the NGLW process using material thicknesses up to 20 mm. The results are compared with those obtained with gas-tungsten arc (GTA) welding. While further work is required on thicker test pieces, preliminary results suggest that the longitudinal tensile residual stresses in NGLW joints are 30–40% lower than those for GTA welds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.