Abstract

The comparative efficacies of seven published McMaster method modifications for faecal egg counting were evaluated on pig faecal samples containing Ascaris suum eggs. Comparisons were made as to the number of samples found to be positive by each of the methods, the total egg counts per gram (EPG) of faeces, the variations in EPG obtained in the samples examined, and the ease of use of each of the methods. Each method was evaluated after the examination of 30 samples of faeces. The positive samples were identified by counting A. suum eggs in one, two and three sections of newly designed McMaster chamber. In the present study compared methods were reported by: I—Henriksen and Aagaard [Henriksen, S.A., Aagaard, K.A., 1976. A simple flotation and McMaster method. Nord. Vet. Med. 28, 392–397]; II—Kassai [Kassai, T., 1999. Veterinary Helminthology. Butterworth–Heinemann, Oxford, 260 pp.]; III and IV—Urquhart et al. [Urquhart, G.M., Armour, J., Duncan, J.L., Dunn, A.M., Jennings, F.W., 1996. Veterinary Parasitology, 2nd ed. Blackwell Science Ltd., Oxford, UK, 307 pp.] (centrifugation and non-centrifugation methods); V and VI—Grønvold [Grønvold, J., 1991. Laboratory diagnoses of helminths common routine methods used in Denmark. In: Nansen, P., Grønvold, J., Bjørn, H. (Eds.), Seminars on Parasitic Problems in Farm Animals Related to Fodder Production and Management. The Estonian Academy of Sciences, Tartu, Estonia, pp. 47–48] (salt solution, and salt and glucose solution); VII—Thienpont et al. [Thienpont, D., Rochette, F., Vanparijs, O.F.J., 1986. Diagnosing Helminthiasis by Coprological Examination. Coprological Examination, 2nd ed. Janssen Research Foundation, Beerse, Belgium, 205 pp.]. The number of positive samples by examining single section ranged from 98.9% (method I), to 51.1% (method VII). Only with methods I and II, there was a 100% positivity in two out of three of the chambers examined, and FEC obtained using these methods were significantly ( p < 0.01) higher comparing to remaining methods. Mean FEC varied between 243 EPG (method I) and 82 EPG (method IV). Examination of all three chambers resulted in four methods (I, II, V and VI) having 100% sensitivity, while method VII had the lowest 83.3% sensitivity. Mean FEC in this case varied between 239 EPG (method I) and 81 EPG (method IV). Based on the mean FEC for two chambers, an efficiency coefficient (EF) was calculated and equated to 1 for the highest egg count (method I) and 0.87, 0.57, 0.34, 0.53, 0.49 and 0.50 for remaining methods (II–VII), respectively. Efficiency coefficients make it possible not only to recalculate and unify results of faeces examination obtained by any method but also to interpret coproscopical examinations by other authors. Method VII was the easiest and quickest but least sensitive, and method I the most complex but most sensitive. Examining two or three sections of the McMaster chamber resulted in increased sensitivity for all methods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.