Abstract
Objectives: The main objective of the study was to compare functional outcome and complications associated with a proximal femoral nail, an intramedullary device with those of a traditional extramedullary device, the dynamic hip screw, in patients with unstable trochanteric fracture. Method: In this prospective, randomized study, total of 86 patients were randomized to the intramedullary group [Group A ( n = 40)] or the extrmedullary group [Group B ( n = 46)]. All relevant perioperative information and complications were recorded, and assessments of functional outcome were made. Results: The extramedullary group required a longer operative time (p value 0.001) and was associated with greater blood loss (p value 0.002) than the intramedullary group. The re-operation rate as well, was lower in the group A compared with the group B, although there were no statistically significant difference in the overall complication rate between the two groups (p value 0.221). There were no significant differences in functional outcome between both groups. Conclusions: The intramedullary device is useful in the treatment of unstable trochanteric fractures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Biomedical and Advance Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.