Abstract

Background and Study Aim: Typhoid (Enteric) fever is a systemic infection caused by Salmonella Typhi and Salmonella Paratyphi. It is endemic in the developing countries including Egypt. Different diagnostic tools can achieve diagnosis and include cultures from the blood, stool, bone marrow, rarely urine for isolation of the organism. Antibody detection by Widal test and relatively recent typhoid are also used. The current study aimed at comparing the most commonly used antibody detection Widal test with the rapid antibody detection typhidot for diagnosis of typhoid fever among Egyptian adults. Patients and Methods: The study included 140 patients who are presented with picture suggestive of typhoid fever. Confirmed cases after the blood culture were included in the final analysis. Widal and typhidot tests were performed in all patients and were compared for sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy. Results: 45 patients out of 140 were diagnosed as typhoid fever by blood culture. Out of them, Widal test was positive in 39 patients with sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 86.7%, 89.5%, 79.5%, 93.4% and 88.5% respectively. Typhidot test was positive in 42 patients with sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 93.3%, 90.6%, 82.3%, 96.6%, and 91.4% respectively (P = 0.00). Conclusions: Typhidot test is reliable, simple highly sensitive and specific test in diagnosing typhoid fever when compared with Widal test.

Highlights

  • Typhoid (Enteric) fever, a systemic infection, is caused mainly by Salmonella typhi (S. typhi) and Salmonella paratyphi (S. paratyphi) [1]

  • Widal and typhidot tests were performed in all patients and were compared for sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy

  • Widal test was positive in 39 patients with sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 86.7%, 89.5%, 79.5%, 93.4% and 88.5% respectively

Read more

Summary

Introduction

Typhoid (Enteric) fever, a systemic infection, is caused mainly by Salmonella typhi (S. typhi) and Salmonella paratyphi (S. paratyphi) [1]. Typhoid (Enteric) fever is a systemic infection caused by Salmonella Typhi and Salmonella Paratyphi It is endemic in the developing countries including Egypt. Widal and typhidot tests were performed in all patients and were compared for sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy. Widal test was positive in 39 patients with sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 86.7%, 89.5%, 79.5%, 93.4% and 88.5% respectively. Typhidot test was positive in 42 patients with sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 93.3%, 90.6%, 82.3%, 96.6%, and 91.4% respectively (P = 0.00). Conclusions: Typhidot test is reliable, simple highly sensitive and specific test in diagnosing typhoid fever when compared with Widal test

Objectives
Methods
Findings
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call