Abstract

The ministernotomy approach with sutureless aortic bioprosthesis may provide an attractive and safe option for aortic valve disease patients. To assess the early and mid-term outcomes of minimally invasive aortic valve replacement (miniAVR) with sutureless vs. standard prostheses. The study involved 76 consecutive patients (51 males and 25 females) with mean age of 63.2 years who were treated with miniAVR between 2015 and 2022. They were divided into 2 subgroups: group I (n = 40) subjects with sutureless bioprostheses and group II (n = 36) with standard prostheses implanted. Early and mid-term outcomes were evaluated. A probability of survival was estimated by means of the Kaplan-Meier method. No conversion to complete sternotomy was necessary. The median (minimum; maximum) aorta cross clamping and cardio-pulmonary bypass times were 49 (27; 84) and 70 (40; 188) minutes in group I whereas 69 (50; 103) and 95 (69; 170) minutes in group II, respectively (p < 0.001). In-hospital mortality was 5.0% (n = 2) and 2.8% (n = 1) in group I vs. II, respectively (ns). Permanent ICD implantation was performed in 8 (20.0%) in group I and in 3 (8.3%) subjects in group II. In the discharge echocardiography, the function of all prostheses was correct. Five-year probability of survival was much lower in group I (0.75 ±0.10) than in group II (0.94 ±0.04). No wound infection or sternum instability was noted. Intraoperative advantages of miniAVR procedures for aortic valve patients with sutureless bioprostheses do not translate directly into improved early and middle-term outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call