Abstract

Amide proton transfer weighted imaging (APTw), intravoxel incoherent motion (IVIM), and positron emission tomography (PET) imaging all have the potential to characterize solitary pulmonary lesions (SPLs). To compare APTw and IVIM with PET imaging for distinguishing between benign and malignant SPLs and their subtypes. Prospective. Ninety-five patients, 78 with malignant SPLs (including 48 with adenocarcinoma [AC] and 17 with squamous cell carcinoma [SCC]), and 17 with benign SPLs. Fast spin-echo (FSE) T2WI, FSE APTw and echo-planar imaging IVIM, MR-base attenuation correction (MRAC), and PET imaging on a 3-T whole-body PET/MR system. The magnetization transfer ratio asymmetry (MTRasym) at 3.5 ppm, diffusion coefficient (D), pseudo diffusion coefficient (D*), perfusion fraction (f), and the maximum standardized uptake value (SUVmax) were analyzed. Individual sample t-test, Delong test, Pearson's correlation analysis, and area under the receiver operating characteristic curve (AUC). P < 0.05 indicated statistical significance. The MTRasym and SUVmax were significantly higher, and D was significantly lower in the malignant group (3.3 ± 2.6 [%], 7.8 ± 5, and 1.2 ± 0.3 [×10-3 mm2 /second]) compared to the benign group (-0.3 ± 1.6 [%], 3.1 ± 3.8, and 1.6 ± 0.3 [×10-3 mm2 /second]). The MTRasym and D were significantly lower, and SUVmax was significantly higher in the SCC group (0.8 ± 1.0 [%], 1.0 ± 0.2 [×10-3 mm2 /second] than in the AC group (4.1 ± 2.6 [%], 1.3 ± 0.3 [×10-3 mm2 /second], 6.7 ± 4.6). Besides, the combination (AUC=0.964) of these three methods showed higher diagnostic efficacy than any individual method (AUC=0.917, 0.851, 0.82, respectively) in identifying malignant and benign SPLs. However, APTw showed better diagnostic efficacy than the combination of three methods or PET imaging alone in distinguishing SCC and AC groups (AUC=0.934, 0.781, 0.725, respectively). APTw, IVIM, and PET imaging are all effective methods to distinguish benign and malignant SPLs and their subtypes. APTw is potentially more capable than PET imaging of distinguishing lung SCC from AC. 2 TECHNICAL EFFICACY: Stage 2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.