Abstract

PurposeTo report a case of inadvertent anterior chamber and cornea stromal injection with high dose antibiotics and steroids during cataract operation.MethodsDuring cataract operation on a 78 year-old female patient, high dose gentamicin (20 mg/0.5 ml) and dexamethasone (2 mg/0.5 ml) were inadvertently injected into the anterior chamber and cornea stroma when making cornea edema for sealing of the incision sites. Anterior chamber irrigation with balanced salt solution (BSS) was immediately administered. On postoperative day one, extensive cornea edema was noted, and best-corrected visual acuity was 0.2. Descemet's membrane folds were observed around the corneal incision sites. Topical 5% NaCl and 1% prednisolone were started.ResultsFour weeks postoperatively, corneal edema began to reduce significantly. At four months postoperatively, corneal edema fully resolved, and best-corrected visual acuity was 0.8. However, some Descemet's membrane folds still remained, and a decrease in the number of endothelial cells was noted by specular microscope.ConclusionsIn this case involving anterior chamber and cornea stromal injection with high dose antibiotics and steroids, immediate anterior chamber irrigation with balanced salt solution seemed an appropriate management, and the patient's long-term visual acuity appears good. To prevent such mistakes, precise labeling of all solutions and use of different syringe needles should be considered.