Abstract

The aims of the present study were to quantify lower limb kinetics and kinematics during walking and slow jogging of below-knee amputee athletes and to demonstrate the usefulness of the additional information provided by kinetic analyses as compared to that of kinematic assessments alone. Kinematic and force platform data from three amputee subjects were collected while the subjects walked and jogged in the laboratory. Results indicated that neither prosthesis (SACH and an energy-storing carbon fiber or ESCF) emulated the kinetics or the kinematics of so-called normal gait during walking. While the knee joint on the prosthetic side clearly tended to be biased toward extension during stance, the knee flexors were dominant and acted concentrically during this phase of the gait cycle. An examination of prosthetic limb hip and knee joint kinetics at both cadences revealed the functional role played by the hamstrings early in stance. The results indicated that with increasing cadence, less variability, measured by coefficients of variation, was evident in the kinematic data while the opposite was true for the kinetics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.