Abstract

This study reports on the implementation of Bayesian inference to improve the estimation of remote-depth profiling for low-level radioactive contaminants with a low-resolution NaI(Tl) detector. In particular, we demonstrate that this approach offers results that are more reliable because it provides a mean value with a 95% credible interval by determining the probability distributions of the burial depth and activity of a radioisotope in a single measurement. To evaluate the proposed method, the simulation was compared with experimental measurements. The simulation showed that the proposed method was able to detect the depth of a Cs-137 point source buried below 60 cm in sand, with a 95% credible interval. The experiment also showed that the maximum detectable depths for weakly active 0.94-μCi Cs-137 and 0.69-μCi Co-60 sources buried in sand was 21 cm, providing an improved performance compared to existing methods. In addition, the maximum detectable depths hardly degraded, even with a reduced acquisition time of less than 60 s or with gain-shift effects; therefore, the proposed method is appropriate for the accurate and rapid non-intrusive localization of buried low-level radioactive contaminants during in situ measurement.

Highlights

  • During the life cycle of nuclear facilities, a significant amount of radioactive waste is generated, resulting in large-scale land and building contamination

  • Various non-destructive techniques have been developed for remote-depth profiling including the relative attenuation method [9,10], principal component analysis (PCA) [11,12,13], and the approximate three-dimensional linear-attenuation method [14,15,16]

  • Depth Estimation of the Buried Cs-137 Based on Simulated Spectra

Read more

Summary

Introduction

During the life cycle of nuclear facilities, a significant amount of radioactive waste is generated, resulting in large-scale land and building contamination Characterization of these wastes is critical for decommissioning those contaminated sites because it can provide essential information related to design specifications and project planning required for environmental restoration [1,2,3]. Examples of wastes commonly encountered during the decommissioning of nuclear facilities include wastes buried inside such porous materials [5,6,7] Traditional destructive methods, such as logging and core sampling, have been used for depth estimation; they are expensive and time-consuming [7,8]. The relative attenuation method takes the relative difference in the Sensors 2019, 19, 5365; doi:10.3390/s19245365 www.mdpi.com/journal/sensors

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call