Abstract
Background. This is a retrospective study of early and long-term results of composite valve graft replacement of the aortic root.Methods and Results. Between July 1974 and July 1997, 244 patients underwent aortic root replacement with a composite valve graft. Mean age was 54 ± 15 years. The inclusion technique was used in 178 patients (73.0%), the open technique in 65 (26.5%), and the Cabrol II technique in 1 patient (0.5%). Hospital mortality was 7.8% (70% confidence limit, 6.1% to 9.5%). Independent determinants of hospital mortality were preoperative creatinine level more than 150 μmol/L (p = 0.04), prolonged cardiopulmonary bypass time (p = 0.006), intraoperative technical problems (p = 0.048), and year of operation (p = 0.015). Follow-up was 99.6% complete, median 96 months (range, 2 to 256 months). Fifty-seven patients (25.3%; 70% confidence limit, 22.4% to 28.2%) died during follow-up. Cumulative survival at 5, 10, and 20 years was 76%, 62%, and 33%. Independent risk factors for late death were postoperative complications (p = 0.027), technique for coronary reattachment (p = 0.028), and concomitant aortic arch operation (p = 0.01). Twenty patients (8.8%; 70% confidence limit, 7.0% to 10.6%) underwent reoperation on the aortic root. Estimated freedom from reoperation for pseudoaneurysms at 3 years was 96% in the inclusion group and 94% in the open group (p = 0.236).Conclusions. Aortic root replacement with a composite valve graft can be performed with low hospital mortality and morbidity. Pseudoaneurysms did occur in the inclusion group, but also in the open group.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have