Abstract

In this study we investigated the influence of technical factors (positioning, background (BG) correction and attenuation correction) on qualitative and quantitative (absolute (AU) and relative (RU) uptake) assessment of feline kidneys with (99m)technetium labelled dimercaptosuccinic acid ((99m)Tc-DMSA). Eleven healthy adult cats were included. Influence of BG and depth correction on quantitative assessment was evaluated. Depth correction was based on the geometric mean method (using dorsal and ventral images) and the use of two standards placed over each individual kidney. Visual evaluation showed superiority of dorsal and ventral over lateral positioning due to increased separation of the kidneys permitting region of interest (ROI) placement without overlap. No apparent influence of BG correction was found for RU. However, AU was systematically overestimated without BG correction. Depth correction did not seem to affect RU in most cases, however, in some cats the differences were not negligible. The values for AU without depth correction were lower compared to depth corrected values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.