Abstract

Background: The Guardian Connect continuous glucose monitoring (CGM) system displays current and trending sensor glucose (SG) via smartphone; records insulin, carbohydrate and exercise; and sends predictive high and low SG alerts up to one hour in advance. When used with the Sugar.IQ diabetes assistant application, personalized insights based on behavior patterns (e.g., food log or insulin dose entry) and glycemic outcomes can be tracked with the Glycemic Assist feature. Methods: System data uploaded between June-November of 2018, by 1765 individuals with diabetes were analyzed. Time in target glucose range (TIR, 70-180 mg/dL) and the Glucose Management Indicator (GMI) were compared between those who used (N=530) or did not use Sugar.IQ. Both groups had ≥5 days of SG data and similar demographic and initial glucose profiles. Results: System users had a mean GMI of 7.1%, mean±SD SG of 157.0±49.1mg/dL (8.7±2.7mmol/L), and a mean TIR of 64.5%, over the data upload period. When predictive alerts were enabled, excursions were avoided after 31% of high SG alerts and 62% of low SG alerts. Those who accessed Sugar.IQ experienced a TIR increase of 2.7% (p=0.006) and a mean SG decrease of -3.0% (p<0.001), with reductions in SD of SG (47.9mg/dL to 41.5mg/dL, p<0.001) and coefficient of variation of SG (0.32 to 0.29, p<0.001), versus those who did not. Their GMI was also 6.8% versus 6.9% (p=0.007). Those who tracked food at least once/day increased TIR by 5% (p<0.001). Users considered 88% of insights helpful. Discussion: The Guardian Connect CGM system with Sugar.IQ may advance patient understanding of glucose trends, aid in behavioral change that improves therapy adherence, and lead to better glycemic outcomes. Disclosure S. Arunachalam: Employee; Self; Medtronic. Y. Zhong: None. S. Abraham: Employee; Self; Medtronic MiniMed, Inc. P. Agrawal: Employee; Self; Medtronic MiniMed, Inc. Stock/Shareholder; Self; Medtronic. R. Vigersky: Employee; Self; Medtronic MiniMed, Inc. T.L. Cordero: Employee; Self; Medtronic. F.R. Kaufman: Employee; Self; Medtronic.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.