Abstract
The operation of 25 solid oxide cells stacks in steam electrolysis mode over 9000 hours is reported. The stack has been operated at current densities of 0.57 and 0.72 A/cm2, using a 50% steam conversion, in the 750-780°C temperature range. Performance degradation rates of 2.30%/ kh are reported, with some non-homogeneity in the stack repeat units behavior observed. Stack repeat units located at the bottom of the stack feature degradation rates below 2%/kh. The possibility to use the operating temperature as a buffer to counter the performance degradation is highlighted. The stack performance was not affected by incidents that occurred during the test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.