Abstract

Hydrogen production through water electrolysis is one of the key processes required in the conversion of electricity to fuels. Carbon free hydrogen produced through water electrolysis can be used as a fuel for hydrogen powered applications (such as fuel cell cars) or grid injection, or as a reactant in downstream processes to produce synthetic fuels such as SNG or methanol. Among available technologies, high temperature electrolysis potentially offers significantly higher electrical to chemical conversion efficiencies compared to alkaline and PEM electrolysers, with values in excess of 100% achievable if additional thermal energy is supplied to the system. High temperature electrolysers are essentially solid oxide fuel cells operated in reverse. Hence, the development of solid oxide electrolysers (SOE) has hugely benefited from the intensive research carried out for the development of Solid Oxide Fuel Cells (SOFCs) in the past decades. A 25 cells stack manufactured by Topsoe Fuel Cells has been tested at EIFER in high temperature electrolysis mode at about 750°C and current densities of 0.57 and 0.72 A/cm2. The applied steam conversion rate was 50%, with a 90 % absolute humidity gas feed. The total duration of the test was almost 9100 hours, split between 8300 current hours and 800 standby hours induced by incidents that occurred during the test. Incidents included losses of the steam and current supplies. After each incident, the stack performance was recovered, indicating a good robustness of the stack towards unexpected and potentially damaging conditions. The main issue during the test has been the considerable increase of the voltage drop between the positive end plate and the bottom stack repeat unit (SRU), before a sharp improvement occurred after about 2000 hours of operation, which has influenced the stack temperature distribution and in turn individual SRU degradation. The maximum observed voltage drop culminated at 2.73 V, before stabilising around 0.6V. The stack has shown an overall voltage degradation of 2% per thousand hours, as can be seen on Figure 1. The corresponding voltage losses were 613 mV and 678 mV per thousand hours, for 0.57 and 0.72 A/cm2 current densities, respectively. This in turn corresponds to an average degradation in the range 0.24 – 0.27 mV per thousand hours per SRU. Moreover, the stack temperature has been adjusted on a few occasion during the test, which highlighted the possibility of using the wide operating temperature range of the solid oxide technology to counter balance the stack degradation and increase the lifetime. Indeed, allowing the stack to increase at a rate of 3°C per thousand hours produced a reduced degradation rate of 1.80 % per thousand hours. Figure 1

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.