Abstract
This study investigated the effects of various factors on the applicability of static modulus of elastic to early determination by warm water curing at 40℃. As a result, it was clarified that even if pre-curing time, type of coarse aggregate, Bulk volume of coarse aggregate per unit volume of concrete and concrete temperature were different, static elastic modulus of concrete using various cements could be estimated by the linear equation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.