Abstract
Background and ObjectiveLarge, uniformly spaced, complex and time varying datasets derived from high resolution medical image velocimetry can provide a wealth of information regarding small-scale transient physiological flow phenomena and pulsation of anatomical boundaries. However, there remains a need for interpolation techniques to effectively reconstruct a fully 4-dimensional functional relationship from this data. This paper presents a preliminary evaluation of a 4-dimensional local radial basis function (RBF) algorithm as a means of addressing this problem for laminar flows. MethodsA 4D interpolation algorithm is proposed based on a Local Hermitian Interpolation (LHI) using a combination of multi-quadric RBF with a partition of unity scheme. The domain is divided into uniform sub-systems with size restricted to immediately neighbouring points. The validity of the algorithm is first established on a known 4D analytical dataset and a CFD based laminar flow phantom. Application is then demonstrated through characterisation of a large 4D laminar flow dataset obtained from magnetic resonance imaging (MRI) measurements of cerebrospinal fluid velocities in the brain. ResultsPerformance of the algorithm is compared to that of a quad-linear interpolation, demonstrating favourable improvement in accuracy. The technique is shown to be robust, computationally efficient and capable of refined interpolation in Euclidean space and time. Application to MR velocimetry data is shown to produce promising results for the 4D reconstruction of the transient flow field and movement of the fluid boundaries at spatial and temporal locations intermediate to the original data. ConclusionThis study has demonstrated feasibility of an accurate, stable and efficient 4-dimensional local RBF interpolation method for large, transient laminar flow velocimetry datasets. The proposed approach does not suffer from ill-conditioning or high computational cost due to domain decomposition into local stencils where the RBF is only ever applied to a limited number of points. This work offers a potential tool to assist medical diagnoses and drug delivery through better understanding of physiological flow fields such as cerebrospinal fluid. Further work will evaluate the technique on a wider range of flow fields and against CFD simulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.