Abstract

We carried out the three-dimensional (3-D) mechanical design of a 2-m-long 20 T common-coil dipole magnet and provided solutions for coil stress management. Instead of using flared ends to make space for the beam pipe, the prototype magnet is designed with a coil configuration which consists of four Nb3Sn and six Bi-2212 flat racetrack coils. The designed peak coil field is 20.4 T at the operating current of 14 700 A. The operating margin is 11% on the load line at 4.2 K. The magnitude of the calculated Lorentz force for 1/8 model is around 1562, 405, and 206 t for the horizontal, vertical, and axial directions, respectively. The special coil configuration and such significant magnetic force bring unprecedented challenges in applying preload to coils and optimizing the coil stress and the stress in the other components. By using an extended aluminum shell and a split yoke assembly, we minimized the coil end effects and applied a uniform and large enough preload to the coil straight section and the coil ends. This paper presents the stress analysis and the optimized 3-D mechanical design of the magnet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.