Abstract

Background: Extracellular Vesicles (EVs) represent stable, tissue specific nano-sized particles that reflect the conditional state of their tissue of origin. Here, the dynamic release and phenotype of kidney EVs was characterized and quantified during Normothermic Machine Perfusion (NMP) of Expanded-Criteria Donor (ECD) kidneys to examine whether EVs could function as a potential biomarker for assessing kidney quality before transplantation. Materials & Methods: Eight discarded ECD kidneys (~13 ± 5 hours of cold ischemia, age 68 ± 7 (mean ± standard deviation), all male) were perfused in a closed system at 37 0C for 6 hours. Perfusates were taken before and at 1, 3 and 6 hours of NMP and examined with Nanoparticle Tracking Analysis (NTA) and Imaging Flow Cytometry (IFCM). For IFCM, perfusates were stained with the tetraspanins CD9, CD63 or CD81 (general EV markers), or a mix of these three markers in combination with CFDA-SE (a non-fluorescent molecule that acquires fluorescent properties after cleavage by intravesicular esterases) to identify, quantify and characterize EVs. Results: Analysis of perfusates with NTA revealed that the majority of nanoparticles present in the perfusates are <300 nm. For CFSE and the mix of tetraspanin double-positive EVs, we observed a ~700/ 740/ 560 fold increase compared to EV levels before perfusion at 1, 3 and 6 hours of NMP, respectively. Analysis of EV concentrations with crude donor characteristics (e.g. age, cold ischemia time (CIT), kidney weight) and NMP viability characteristics (renal flow, renal flow resistance, urine production) revealed that double-positive EV are negatively correlated with CIT whilst positive correlations were found with donor age after the first hour of NMP. Furthermore, tetraspanin CD81 was found to represent the majority (~75%) of the excreted double-positive EV (CD9: ~16%/ CD63 ~8%) (Figure). Conclusion: EVs <300 nm are released by ECD kidneys during NMP with highest excretion levels during the first hour of perfusion. Tetraspanin CD81 is predominantly present on these EVs, and EV concentrations were shown to be correlated with well-established indicators of kidney quality such as donor age and CIT. The characterization of the excreted EVs as well as their correlation with clinical parameters provide a starting point to study their role as potential biomarkers of kidney quality.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call