Abstract

A modulated training pattern for intra-panel interface is proposed and is applied to design power-efficient clock and data recovery (CDR) circuits for intra-panel interface. By modulating the position of the rising edge of the training pattern, the number of the delay cells to generate the multi-phase clock to capture display data safely is reduced. As a result, power, area, and electro-magnetic interference characteristics can be improved over the conventional training pattern. A phase-locked loop-based CDR circuit with the proposed scheme in a 65 nm CMOS technology is designed. The measured lock range was between 6 and 10 Gbit/s and the power efficiency was 0.38 mW/Gbit/s at 10 Gbit/s inputs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.