Abstract

There is limited experience with continuous glucose monitoring (CGM) in intensive care units (ICUs). We assessed the effectiveness, safety, and accuracy of real-time CGM use in COVID-19 ICUs. We pooled data from three academic centers using hybrid protocols combining point of care (POC) blood glucose (BG) with non-adjunctive CGM. At hospitals A and B, CGM was used non-adjunctively with POC at least every 6 hours. At hospital C, POC BG was performed every two hours. We also examined CGM performance during lowest pAO2, oxygen saturation, pH, and mean arterial pressure. Of 169 patients, mean age was 60.9±12.2 years, and 82%, 93%, and 62% received corticosteroids, mechanical ventilation, and vasopressors respectively. Median duration of IV insulin was 118, 156, and 50 hours at hospitals A, B, and C respectively. Mean POC BG frequency was 10.2±6.1, 7.0±5.2, and 16±6.5 times/day on day 1 of IV insulin and 6.7±3.1, 6.0±3.5, and 12.2±5.8 times/day thereafter. The median percent CGM time in range (TIR, 70-180mg/dl) was 72%, 70% and 46% during IV insulin. Median time <70mg/dl was <0.1% for all hospitals. The absolute relative difference between CGM and POC did not correlate with hemodynamic instability, Figure. This data indicates hybrid monitoring can reduce POC frequency while safely maintaining glucose. Sensor-meter agreement was not associated with abnormal physiologic parameters and requires further study. Disclosure E.R.Faulds: Advisory Panel; Dexcom, Inc., Other Relationship; A1Control, LLC, Research Support; Dexcom, Inc., Speaker's Bureau; Dexcom, Inc., Medscape. M.Garcia: None. S.Chandra: None. F.J.Pasquel: Consultant; Dexcom, Inc., Medscape, Research Support; Dexcom, Inc., Ideal Medical Technologies. K.M.Dungan: Board Member; Elsevier, Consultant; Eli Lilly and Company, Dexcom, Inc., Other Relationship; UpToDate, Research Support; Dexcom, Inc., Abbott, ViaCyte, Inc., Sanofi, Speaker's Bureau; Academy for Continued Healthcare Learning, Cardiometabolic Health Congress, Medscape, Integritas. Y.Badakhshi: None. A.Boutsicaris: None. M.C.Exline: Other Relationship; Abbott Nutrition. J.Hester: None. L.G.Jones: None. M.Mcnett: Research Support; Dexcom, Inc., National Institutes of Health. J.D.Miller: Advisory Panel; MannKind Corporation, Employee; Medtronic, Research Support; Dexcom, Inc. R.Shah: None.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call