Abstract

Ho-doped yttrium lithium fluoride chirped pulse amplification (CPA) is implemented with a high-gain regenerative amplifier (RA) and a two-stage booster amplifier. We demonstrate the generation of 52.5 mJ pulses with a duration of 2.4 ps at a 1 kHz repetition rate. A peak power of 17 GW is achieved for the 2050 nm pulses. The CPA displays a remarkably high stability with a pulse-to-pulse rms as low as 0.23%. The RA operates without any signs of bifurcation and delivers 12 mJ pulses. Seeding the booster amplifier with the RA output scales the pulse energy linearly up into the 50-60 mJ range. The amplifier system is operated at room temperature and shows a high optical-to-optical efficiency of 20.3% with respect to the optical pump power.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.