Abstract

It is important for the evaluation of the sewage pump to secure the passing diameter large compared to a pump diameter. But the impeller exit width is too small when we design by a conventional design method Therefore we cannot apply to non-clog type impellers for a sewage pump. A new design method for the centrifugal pump impeller theoretically was suggested This design method applied to a single blade centrifugal pump impeller. Pump performance, pressure distribution and behavior of radial thrust were measured about this impeller. Furthermore, we investigated the validity of the design by using CFD analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.