Abstract
IntroductionFialuridine (FIAU) is a nucleoside analog that is a substrate for bacterial thymidine kinase (TK). Once phosphorylated by TK, [124I]FIAU becomes trapped within bacteria and can be detected with positron emission tomography/computed tomography (PET/CT). [124I]FIAU PET/CT has been shown to detect bacteria in patients with musculoskeletal bacterial infections. Accurate diagnosis of prosthetic joint infections (PJIs) has proven challenging because of the lack of a well-validated reference. In the current study, we assessed biodistribution and dosimetry of [124I]FIAU, and investigated whether [124I]FIAU PET/CT can diagnose PJIs with acceptable accuracy. MethodsTo assess biodistribution and dosimetry, six subjects with suspected hip or knee PJI and six healthy subjects underwent serial PET/CT after being dosed with 74MBq (2mCi) [124I]FIAU intravenously (IV). Estimated radiation doses were calculated with the OLINDA/EXM software. To determine accuracy of [124I]FIAU, 22 subjects with suspected hip or knee PJI were scanned at 2–6 and 24–30h post IV injection of 185MBq (5mCi) [124I]FIAU. Images were interpreted by a single reader blinded to clinical information. Representative cases were reviewed by 3 additional readers. The utility of [124I]FIAU to detect PJIs was assessed based on the correlation of the patient's infection status with imaging results as determined by an independent adjudication board (IAB). ResultsThe kidney, liver, spleen, and urinary bladder received the highest radiation doses of [124I]FIAU. The effective dose was 0.16 to 0.20mSv/MBq and doses to most organs ranged from 0.11 to 0.76mGy/MBq. PET image quality obtained from PJI patients was confounded by metal artifacts from the prostheses and pronounced FIAU uptake in muscle. Consequently, a correlation with infection status and imaging results could not be established. Conclusions[124I]FIAU was well-tolerated in healthy volunteers and subjects with suspected PJI, and had acceptable dosimetry. However, the utility of [124I]FIAU for the clinical detection of PJIs is limited by poor image quality and low specificity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.