Abstract
Objective: Radiation pneumonitis and cardiac effects are directly related to the irradiated lung and heart volumes in the treatment fields. The central lung distance (CLD) from a tangential breast radiograph is shown to be a significant indicator of ipsilateral irradiated lung volume based on empirically derived functions which accuracy depends on the actual measured volume in treatment position. A simple and accurate linear relationship with CLD and retrospective analysis of the pattern of dose volume of lung and heart is presented with actual volume data from a CT simulator in the treatment of breast cancer. Materials & Methods: The heart and lung volumes in the tangential treatment fields were analyzed in 45 consecutive (22 left and 23 right breast) patients referred for CT simulation of the cone down treatment. All patients in this study were immobilized and placed on an inclined breast board in actual treatment setup. Both arms were stretched over head uniformly to avoid collision with the scanner aperture. Radiopaque marks were placed on the medial and lateral borders of the tangential fields. All patients were scanned in spiral mode with slice width and thickness of 3 mm each, respectively. The lung and heart structures as well as irradiated areas were delineated on each slice and respective volumes were accurately measured. The treatment beam parameters were recorded and the digitally reconstructed radiographs (DRRs) were generated for the CLD and analysis.