A dual-loop cycle for a domestic refrigerator-freezer (RF) has a large energy saving potential because it has a lower compression ratio due to a higher evaporating temperature in the fresh food compartment (R)-operation compared to a conventional refrigeration cycle, as well as individual optimization flexibility for each loop. In this study, optimizations of dual-loop cycles using R-600a and hydrocarbon (HC) mixtures were individually carried out. Each optimization process included both a theoretical analysis and an experimental investigation. The theoretical analysis was conducted to optimize the specifications of cycle components and the HC mixture compositions for each loop. Based on the experimental results, the energy consumptions of the optimized dual-loop cycles using R-600a and HC mixtures were decreased by 14.2% and 18.6%, respectively, compared with that of a bypass two-circuit cycle using R-600a in the same RF platform.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.