Abstract

A Lorenz–Meutzner cycle (called the “LM cycle”) for a domestic refrigerator-freezer (RF) has energy saving potential because of lower entropy generation in the fresh food compartment (R)-evaporator and lower compression ratio due to higher mean evaporating temperature, compared to a conventional cycle using pure refrigerant. In this study, a thermodynamic analysis for the optimum compositions of hydrocarbon (HC) mixtures and cycle specifications was performed. In addition, the effects of the refrigerant charge, capillary tube, compressor capacity, and mixture composition on the performance of the LM cycle using R-290/R-600 were investigated experimentally. Based on the experimental data, the energy consumption of the optimized LM cycle using R-290/R-600 (40:60%) was 11.2% lower than that of a bypass two-circuit cycle using R-600a in the same RF platform.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.