Abstract

We fabricated self-assembled monolayers(SAMs) onto quartz crystal microbalance(QCM) using viologen, which has been widely used as electron acceptor and electron transfer mediator. We determined the time dependence on resonant frequency shift during self-assembly process and observed the morphology of self-assembled monolayers by STM and investigated the electrochemical behavior of SAMs by cyclic voltammetry. Electrochemical deposition of viologen was investigated using electrochemical quartz crystal microbalance(EQCM). The redox reactions of viologen were highly reversible and the EQCM has been employed to monitor the electrochemically induced adsorption of SAMs during the redok reactions. The total frequency change was about 9.5 Hz, and 7.1 Hz. From the data, we could know the mass change was about 10.16 ng and 7.60 ng, respectively. Finally, the EQCM has been employed to monitor the electrochemically induced adsorption of self-assembled monolayers on Au surfaces.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call