Abstract

This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (4.0 (W) 11.0 (L) 2.6(H) m) with corridor and attic for preheating using CFD (Computational Fluid Dynamics) simulation. The experimental weaning piglet house was consisted of a corridor, an attic, 4 rooms (3.0 (W) 2.75(L) m), 3 fences (0.7(H) m), 5 air inlets and 2 exhaust fans (0.4 (D) m) and simulated using CFD code, FLUENT. The simulation results for the experimental weaning piglet house showed that each room was uniformly ventilated under all the experimental conditions and air velocities at 0.1 m above floor are less than 0.15 m/s for 0.75 m/s and 1.0 m/s of air inlet velocity but 0.61 m/s for 1.25 m/s. The simulation results are similar to the measured results. Considering the air flow pattern, ventilating efficiency, air velocity at 0.1 m above floor and cold stress of weaning piglets and so on, the optimum velocity of air inlet might be 1.0 m/s.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.