Abstract

This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2 (W) 12.3 (L) 2.3 (H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520 (W) 300 (L) cm), 3 fences (70 (H) cm), 1 air inlet (350 (W) 2 (H) cm) and 1 exhaust fan (50 (D) cm), and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result f3r the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.