The flash point is an important indicator of the flammability of a chemical. In this study, the flash points for the n-propanol+n-butanol and n-propanol+acetic acid systems were measured by Tag open-cup apparatus. The experimental data were compared with the values calculated by the Raoult's law and optimization method based on van Laar and UNIQUAC equations. The calculated values by optimization method were found to be better than those based on the Raoult's law.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.