Lower flash points for flammable binary systems, ethylbenzene+n-propanol, n-propionic acid+ethylbenzene and n-propionic acid+o-xylene, were measured by Tag open cup tester. These binary solutions exhibited the minimum flash point behavior, which leads to a minimum on the flash point vs composition curve. The experimental data were compared with the values calculated by the flash point prediction models based on the van Laar and Wilson equations. As can be seen from the A.A.D., the calculated values based on the Wilson equation were found to be better than those based on the van Laar equation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.