Abstract

ABSTRACT Propellent should be pressurized inside the turbopump to gain high thrust in a projectile. Turbopump is composed of an inducer, which prevents impeller performance deterioration, and an impeller. Several types of cavitation occur inside the inducer, numerous experiments and CFD simulations are conducted. Though, an inducer takes only small portion of total head of the pump and the following impeller determines whole turbopump performance. In addition, low inlet pressure makes the flow to be cavitated not only at the inducer, but also at the impeller in real cases. Therefore, flow through an inducer and an impeller should considered simultaneously. In this study, LOX pump composed of an inducer and an impeller is analyzed by using commercial CFD code ANSYS CFX 13.0. Non-cavitating flow with high inlet pressure and cavitating flow with low inlet pressure are both simulated and head, suction performances are shown. Evolution of the flow and the cavitation by reducing cavitation number and effect of cavitation on pump performance are studied.