Abstract

The method of linear voltammetry in the potentiodynamic mode was used to study the anodic behavior of the W, Ni, Fe, Co alloy waste (wt. %: W 90, Ni 7, Fe 2, Co 1) in a 1 M ammonium carbonate solution. The process of the W, Ni, Fe, Co alloy dissolution under the action of direct and sinusoidal alternating current, was also studied. It was found that the use of alternating current makes it possible to achieve the maximum rate of alloy oxidation, the effect of direct current ensures the process proceeds with the maximum current efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.