Abstract

The main requirements that apply to axial fans and axial compressors of aircraft gas turbine engines include minimum dimensions and weight; high aerodynamic load; high coefficient of performance; wide range of steady work; high reliability. For gas turbine engines, the requirements of minimum weight and dimensions are especially important, since the engines must provide flights at high velocities and altitudes. This study aims to assess the effect of the solidity of the impeller fan on the average radius on the aerodynamic loading of the impeller of an axial fan for an engine with a high bypass ratio. The object of the study is the impeller of the fan. The solidity of the impeller fan on the average radius varied in the range from 1.8 to 0.82, the number of blades of the impeller fan varied from 33 to 15, respectively. The studies in this work were carried out by the method of numerical experiment. The flow in the axial fans was simulated by solving the system of Navier-Stokes equations, which were closed by the SST turbulent viscosity model. Based on the analysis of the results of the study, an assessment is made of the influence of the solidity of the impeller fan at an average radius on the aerodynamic loading of the impeller of an axial fan for an engine with a high bypass ratio. The research results showed that with a decrease in the solidity of the impeller fan at an average radius of 1.8 to 0.82 in operating modes with an axial inlet velocity of 80 to 120 m / s, the impeller fan pressure ratio decreases by 0.11 ... 3.2 %. The maximum decrease in the fan pressure ratio increase for the fan impeller with the parameters studied is 3.2 %, with a decrease in the number of fan blades from 33 to 15, while the total weight of the blades decreases by 54.55 %. The decrease in the solidity on the average radius of the impeller of the studied fan leads to a decrease in the relative sizes of the low-velocity zones at the sleeve and on the periphery and to a decrease in the level of flow unevenness. A further reduction in the level of flow non-uniformity behind the fan is possible when using the boundary layer control in the fan - this is the task of subsequent studies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.