Abstract

Void measurement of a vertical 4×4 rod bundle has been conducted behind a spacer in a steam-water two-phase flow using an advanced X-ray CT scanner and one-dimensional single subchannel analysis without a cross-flow was done. It was found from the experimental results that the cmss-sectional averaged void fraction data behind the spacer could be predicted by the drift-flux model, that the spacer has a negligible effect on the cross-sectional averaged void fraction and that EPRI correlation made it possible to accurately predict the void data. In addition, the simplified single subchannel analysis without the cross-flow between subchannels gave good agreement with data of center subchannels in a quality range of 5% or more. However, the analysis predicted higher void fraction than experimental results in the corner subchannel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.