Void fraction measurement of a vertical ( 4 x 4) rod bundle has been conducted in a steam-water two phase flow, using an advanced X-ray CT scanner. A large amount of rod bundle data was obtained. It was found from the results that the cross-sectional averaged void fraction data for a rod bundle can be correlated by the Drift-Flux model and that the Zuber-Findlay correlation underestimates the data in a void fraction area of 80% or more. This is because the data range over which this correlation was developed, does not cover this experimental range. Therefore, a modified correlation was developed based on the authors' data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.