Abstract

Cross Flow type of heat exchanger seems likely to have superior characteristics designing a large heat transfer surface area per unit volume. In this study, new approached version of counter flow type of heat exchanger by using a 45° inclined plate fin arrangement and employing inserted plate between the fins raw are proposed in order to be up heat transfer enhancement of over all heat transfer coefficient. Four types of exchanger, i.e., conventional cross flow type with inserted plate (I), converted counter flow type with inserted plate (II) (III), and conventional marketing type (IV) are tested by experiment as a parameter of the magnitude of exchanged temperature difference and the mass flow rate. Obtained data are discussed as a relation of effectiveness and number of transfer rate, and exergy transfer. It is cleared that new proposed counter flow type (II) (III) have interesting heat exchanging characteristics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.