Abstract
The evaluation method of neutron dose equivalent was studied on the basis of the albedo type neutron dosimetory to design the personnel dosimeter. The dosimeter was composed of three 6Li210B4O7(Cu) TL elements and one 7Li211B4O7(Cu) element.The equations for assessing thermal, epithermal and fast neutron dose equivalents were derived by 252Cf, 241Am-Be and PuO2 neutron sources.The minimum detectable amount of 6Li210B4O7(Cu) element to thermal neutron was 0.02 mrem. The neutron dose equivalent and the gamma one were evaluated separately within about 20% error in the mixed radiation field.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.