The effect of the upstream flow conditions on the disc stability of the swing check valves was investigated at various upstream flow disturbance sources and distances from the tested check valves. The experimental loop was designed and installed to measure the disc positions, disc back stop load, and differential pressure at flow velocities for 3 inch and 6 inch swing check valves. The selected disturbance sources are elbow and globe valve. The effect of the disc fluctuation is different depending on the type of disturbance and the distance between the disturbance and the check valve. Disturbances generated by elbow and globe valve located upstream from check valve create greater and more violent disc motion than uniform flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.