Abstract

Since contamination of insulating oil causes partial discharge and mechanical malfunction, it is necessary to remove internal fine particles. Currently an electrostatic filter method is being actively studied to remove particles inside the non-conductive liquids, however this method has the drawback of being time-consuming. Recently an electrostatic filter with ion injection has been created to deal with the issue of taking a long time, however there hasn’t been enough research on removing particles of various sizes. This study used an electrostatic filter with an ion injection to remove particles of various sizes. Up to 72% of the 100 mesh-sized particles were removed after using a needle-plate electrode for 180 seconds after adding PE particles to the transformer oil. This result can be applied to studies on electrostatic force-based removal of fine dielectric particles from non-conductive liquids.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.