Abstract
It is shown that significant aging of electrical equipment of power plants, high cost of failures, the need to continue its operation, compliance with safety rules requires increasing the reliability of monitoring the technical condition of insulation. Analysis of existing methods of continuous monitoring of the technical condition of the insulation of the stator winding of a synchronous generator operating in a unit with a transformer showed their significant shortcomings, namely the low sensitivity to changes in insulation damage near the neutral of the stator winding and symmetrical reduction of insulation parameters. This does not allow to detect damage at an early stage of its development. In addition, there is a faulty operation of the controls due to asymmetries of phase voltages. To increase the probability of controlling the insulation parameters of the stator winding of the synchronous generator, the method, principle of construction, algorithm of diagnostic control complex, as well as software algorithm used to process measurement data and determine the insulation parameters of the stator winding based on microprocessor. The probability of control of the proposed method of controlling the insulation of the stator winding of a synchronous generator operating in a unit with a transformer based on the superimposition on the circuit containing the stator winding, AC signals with a frequency lower than the rated frequency, DC voltage, use the energy of the pre-charged capacitor and the calculation of the insulation parameters of the "generator-transformer" unit. Expressions are given to determine the total active resistance relative to the ground and at the place of formation of the shunt connection with the ground, the equivalent insulation capacity, the tangent of the dielectric loss angle in the insulation, the probability of false and indefinite failure, the probability of “suitable” multiparameter control. The expressions necessary for calculating the probability of control of active resistance relative to ground, transient resistance at the place of shunt formation, insulation capacity relative to ground, tangent of dielectric loss angle of stator winding of synchronous generator operating in block with transformer are obtained. Based on the obtained expressions, the probability of the result “suitable” is calculated. The results of calculations can be used in the design of relay protection and diagnostic systems for electrical equipment of new power units, as well as in the reconstruction of existing power units of power plants.
Highlights
Для підвищення вірогідності контролю параметрів ізоляції обмотки статора синхронного генератора запропоновано метод, принцип побудови, алгоритм функціонування діагностичного комплексу контролю, а також алгоритм програмного забезпечення, яке використовується для обробки даних вимірювання і визначення параметрів ізоляції обмотки статора на основі мікропроцесора
It is shown that significant aging of electrical equipment of power plants
compliance with safety rules requires increasing the reliability of monitoring the technical condition of insulation
Summary
Для підвищення вірогідності контролю параметрів ізоляції обмотки статора синхронного генератора запропоновано метод, принцип побудови, алгоритм функціонування діагностичного комплексу контролю, а також алгоритм програмного забезпечення, яке використовується для обробки даних вимірювання і визначення параметрів ізоляції обмотки статора на основі мікропроцесора. Виконано оцінювання вірогідності контролю запропонованого методу контролю ізоляції обмотки статора синхронного генератора, що працює в блоці з трансформатором, який ґрунтується на накладанні на коло, що містить обмотку статора, сигналів змінної напруги частотою, нижчою, за номінальну частоту мережі, напруги постійного струму, використання енергії попередньо зарядженого конденсатора та розрахунку параметрів ізоляції блока «генератор–трансформатор».
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.