Abstract
ABSTRACT:A heat pump dryer for the frozen food needs to preheat the air to a certain tempera-ture where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more effici-ent for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.Keywords:Heat pump(히트펌프), Dryer(건조기), Evaporator(증발기), Cycle(사이클) †Corresponding author Tel.: +82-41-521-9261; fax: +82-41-555-9123 E-mail address: ylee@kongju.ac.kr 기 호 설 명 COP :성적계수α, β :effectiveness-capacitance rate product e :heat exchanger effectivenessṁ :냉매 질량유량 [kg/s]T :온도 [℃]c :비열 [kW/K]