Based on the results of an experimental study of the properties of a small-scale model of passive heat removal, obtained in static and dynamic modes with an interval of 1 second, the statistical characteristics of the main parameters of the system considered as stationary random functions were estimated. The mathematical expectation, variance and normalized correlation function were determined.