Abstract

Corner retaining walls are one of the most common structures of waterworks. Most of them were designed and built several decades ago and have been in operation for a long time. In some cases, there is a deviation from the design prerequisites and the strengthening of reinforced concrete structures of retaining walls is required. The main reason for these deviations is incomplete consideration of the characteristic features of retaining wall structures (including horizontal inter-block joints and secondary inclined cracks), as well as the nature of the loads acting on them. As a result, design horizontal transverse reinforcement is practically not installed in retaining walls that is not required by calculation based on traditional calculation methods.Traditional reinforcement schemes for retaining walls do not provide for the presence of horizontal inter-block joints and horizontal transverse reinforcement. As a result of the research carried out,the method for calculating the stress-strain state and strength of reinforced concrete structures of corner retaining walls with inter-block joints has been improved taking into account secondary stresses. Reinforcement schemes for retaining walls have also been improved.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call