This study aimed to assess clinical efficacy of 4-mm-short implants in patients with posterior severe vertical bone atrophy in the medium- and long-term follow-up. Patients rehabilitated with 4-mm-short implants in the posterior atrophic jaws, with a minimum follow-up of 3 years post-loading, were included in the study. Data were collected for eligible patients, and marginal bone loss (MBL) for each implant was evaluated. The research outcomes were implant failure, MBL and complications. A total of 212 patients with 496 implants were included, resulting in a mean follow-up of 8.02 ± 2.17 years. The implant survival rate was 95.36% (95% CI: 93.12%-97.04%). More implant failures were observed in the maxilla (p = .02) and fewer failures were observed in patients undergoing more number of hygienic sessions per year (p < .001). The average MBL after 1-year-loading was 0.47 mm, increasing to 0.59 mm after 10 years; after 3 years no statistically significant increase in MBL was observed. Maxillary implants showed greater bone loss than mandibular ones (p < .001). More frequent professional oral hygiene sessions per year resulted being related with reduced MBL (p < .001). Four-mm-short implants showed high survival rates with an up to 10-year follow-up. Their use can offer a fixed prosthetic solution for patients with posterior vertical bone atrophy, minimizing surgical invasiveness, rehabilitative times and costs.