Abstract: Three dimensional analysis of steady fully developed laminar flow inside twisted duct of square cross section flow area is studied for Reynolds number range of 100 – 2000 using a commercially available software. Twist ratio used are 2.5, 5, 10 and 20. Heat transfer results are generated for a uniform wall temperature case for Prandtl number range of 0.7 to 20. Maximum values for the product of friction factor and Reynolds number is observed for a twist ratio of 2.5 and Reynold number of 2000. Maximum Nusselt number is observed for the same values along with Prandtl number of 20. Correlations for friction factor and Nusselt number are developed involving swirl parameter. Local distribution of friction factor ratio and Nusselt number across a cross-section is presented. Heat transfer enhancement for Reynold number of 2000 and Prandtl number of 0.7 for twist ratio of 2.5, 5, 10, and 20 are 33 %, 18 %, 10 % and 7 % respectively. The results are significant because it will contribute to development of compact heat exchanger.
Read full abstract