In order to establish a suitable restoring force correction model for enveloped steel jacket (ESJ)-confined seismic-damaged rectangular recycled aggregate concrete-filled steel tubular (RRACFST) columns, based on experimental research, a study of the seismic performance and parameters of ESJ-confined seismic-damaged RRACFST columns was carried out. The restoring force theory, model test, and OpenSees simulation of ESJ-confined seismic-damaged RRACFST columns were conducted. Firstly, a trilinear model of the skeleton curve and a suitable restoring force model for ESJ-confined seismic-damaged RRACFST columns were established. The results were compared with the model test results, and it was found that the two results had good consistency. Secondly, the initial damage of the RRACFST column was simulated by the reducing material properties method, and a correct numerical model for ESJ-confined seismic-damaged RRACFST columns was proposed. The influence mechanism of seismic parameters of the RRACFST column was clarified. Finally, the seismic parameter combination with the best seismic performance for ESJ-confined seismic-damaged RRACFST columns was established; namely, the replacement rate of recycled coarse aggregate is 50%, the concrete strength is C40, the axial compression ratio is 0.3, the strength of the rectangular steel tube is Q345, the wall thickness of the steel tube is 4 mm, and the slenderness ratio is 7.5.
Read full abstract