The pipeline embolization device (PED) is commonly used for intracranial aneurysm treatment. While its effectiveness for certain types of aneurysms is well-established, its efficacy for saccular aneurysms remains controversial. We aimed to assess the long-term outcomes of PED treatment for unruptured intracranial saccular aneurysms. Systematic review and meta-analysis were conducted following PRISMA guidelines. Studies with at least one year of follow-up after PED treatment for saccular aneurysms were included. The primary endpoint was angiographic aneurysm occlusion at long-term follow-up (≥ 12 months), and the secondary outcome was long-term complications. We conducted a meta-regression analysis to explore potential sources of heterogeneity across studies. Eleven studies of 797 patients with 963 aneurysms were included. Long-term angiographic occlusion rate was 85% (95% CI, 77-91%; p < 0.01), symptomatic ischemic stroke rate was 1% (95% CI, 0-3%; p < 0.01), rupture rate was 1% (95% CI, 0-2%; p = 0.02), and intracranial hemorrhage (ICH) rate was 0.2% (95% CI, 0-1%; p = 0.11). Meta-regression analysis revealed a non-significant decreasing trend per year for aneurysmal occlusion, ischemic stroke rate, delayed aneurysmal rupture, and ICH. PED demonstrates high long-term occlusion and low complication rates, suggesting it is a safe and effective treatment option for saccular aneurysms. Additionally, newer devices exhibit reduced thrombogenic profiles and safety with decreasing trends in ICH, ischemic stroke, and delayed aneurysmal rupture.
Read full abstract