PurposeTo evaluate the impact of the iridocorneal angle size (ICAS) on the diurnal intraocular pressure (IOP) in patients with suspected glaucoma (SG).MethodPatients with any eye-pressure lowering medication or previous ocular surgery were excluded. In a retrospective study set, diurnal IOP profiles of 120 patients (205 eyes) within a 48-h period were analysed by regression analysis. Of those eyes, 44 were diagnosed to have glaucoma. The remaining eyes were used as healthy control group (HCG).ResultsThe overall mean IOP was 15.63 mmHg ± 2.72 mmHg and mean ICAS was 23.92° ± 4.74°. In the glaucoma cohort, mean IOP was 18.77 ± 1.86 mmHg and mean ICAS was 25.02° ± 4.96°. In the HCG, mean IOP was 14.77 ± 2.25 mmHg and mean ICAS was 23.62° ± 4.64°. In the total cohort, as well as in the subgroups (HCG or glaucoma), regression analysis showed no significant impact even of the minimum ICAS, which was larger than 10°, on average (P = 0.89), maximum (P = 0.88), and range of IOP (P = 0.49) within 48 h. The difference between glaucoma cohort and HCG cohort was significant in terms of IOP (P < 0.001), but not for minimum ICAS (P = 0.07). Chi-square test showed no increase in prevalence of IOP peaks of > 21 mmHg within 48 h in eyes with an angle between 10° and 20° (P = 0.18).ConclusionAn ICAS of larger than 10° in HCG or glaucoma patients with an open-angle does not influence the minimum, average, maximum or range of IOP. Additionally, an angle size larger than 10° does not allow the prediction of IOP changes in these two cohorts.