BackgroundThere are few data on ventricular fibrillation (VF) initiation in patients with inferolateral J waves. ObjectivesThis multicenter study investigated the characteristics of triggers initiating spontaneous VF in inferolateral J-wave syndrome. MethodsA total of 31 patients (age 37 ± 14 years, 24 male) with spontaneous VF episodes associated with inferolateral J waves were evaluated to determine the origin and characteristics of triggers. The J-wave pattern was recorded in inferior leads in 11 patients, lateral leads in 3, and inferolateral leads in 17. ResultsThe VF triggers (n = 37) exhibited varying QRS durations (176 ± 21 milliseconds, range 119-219 milliseconds) and coupling intervals (339 ± 46 milliseconds, range 250-508 milliseconds) with a right (70%) or left (30%) bundle branch block (BBB) pattern. Trigger patterns were associated with J-wave location: left BBB triggers with inferior J waves and right BBB triggers with lateral J waves. Electrophysiologic study was performed for 22 VF triggers in 19 patients. They originated from the left or right Purkinje system in 6 and from the ventricular myocardium in 10 and were undetermined in 6. Purkinje vs myocardial triggers showed distinct electrocardiographic characteristics in coupling interval and QRS-complex duration and morphology. Abnormal epicardial substrate associated with fragmented electrograms was identified in 9 patients, with triggers originating from the same region in 7 patients. Catheter ablation resulted in VF suppression in 15 patients (79%). ConclusionsVF initiation in inferolateral J-wave syndrome is associated with significant individual heterogeneity in trigger characteristics. Myocardial triggers have electrocardiographic features distinct from Purkinje triggers, and their origin often colocalizes with an abnormal epicardial substrate.